Zhuomao ZM-APS3005DM adjustable DC power supply DC power supply repair notebook necessary
The device can be automatically converted at constant voltage constant current mode, the state decided to compare the results of the load current and the current limit values.
1. constant voltage mode CV
Present current value than the current value of the output limit hour setting, the power supply is in constant voltage mode, then the front panel of the constant voltage (CV)  green indicator light, the output voltage will be controlled and set with the same value, the current It will be with the load changes.
2. The constant current mode (CC)
When the current value of the output current exceeds the limit, the device will work in constant current mode, constant on the front panel lights red indicator ⑨ output current value controlled to the set value, due to the output power can not overload, the output voltage It will be lower than the set value. When the output current is lower than the set value, the device will automatically be converted to constant current state.
  • Product Details
  • Specification
  • Make Inquiry
  • Product Video
The device can be automatically converted at constant voltage constant current mode, the state decided to compare the results of the load current and the current limit values.
1. constant voltage mode CV
Present current value than the current value of the output limit hour setting, the power supply is in constant voltage mode, then the front panel of the constant voltage (CV)  green indicator light, the output voltage will be controlled and set with the same value, the current It will be with the load changes.
2. The constant current mode (CC)
When the current value of the output current exceeds the limit, the device will work in constant current mode, constant on the front panel lights red indicator ⑨ output current value controlled to the set value, due to the output power can not overload, the output voltage It will be lower than the set value. When the output current is lower than the set value, the device will automatically be converted to constant current state.

working environment

 

indoor workplaces and no direct sunlight and large amounts of dust and poor insulation venue.

Relative humidity

<80%

Altitude

<2000m

Temperature

0-40

Storage Environment

 

Location

indoor

Relative humidity

<70%

Temperature

-10 -70